This README file was generated on 2026-02-27 by Elena Steinwender. Last updated: 2026-01-20. ------------------- GENERAL INFORMATION ------------------- // Title of Data: Replication Data and Conference Paper for: Alternative Sorptionsmittel für Absorptionswärmepumpen: Stoffeigenschaften von IL und DES sowie Betriebsverhalten im "gläsernen Demonstrator" // DOI:https://doi.org/10.3217/52nz0-cch75 // Contact Information // Corresponding Author: // Name: Michael Wernhart // Institution: Institute of Thermal Engineering, Graz University of Technology // Email: michael.wernhart@tugraz.at // Repository: // Name: Elena Steinwender // Institution: Institute of Thermal Engineering, Graz University of Technology // Email: elena.steinwender@tugraz.at // Contributors: Michael Wernhart, Elena Steinwender, René Rieberer, Christoph Weinzettl, Marlene Kienberger, Markus Damm, Roland Kalb, Mike Otto, Christian Kemmerzehl // Kind of data: Conference Paper (.pdf), Excel worksheet (.xlsx) and figures (.png) // Date of data collection/generation: 2021-05-25 - 2025-09-30 // Funding sources: This project is funded by the Austrian Research Promotion Agency (“FFG”) under project number FO999905735 with funds from the Climate and Energy Fund and is carried out within the framework of the “Energy Research Program 2022”. // Description of dataset: This dataset contains the data of the publication: Wernhart, M., Steinwender, E., Rieberer, R., Weinzettl, C., Kienberger, M., Damm, M., Kalb, R., Otto, M., Kemmerzehl, C. (2025). Alternative Sorptionsmittel für Absorptionswärmepumpen: Stoffeigenschaften von IL und DES sowie Betriebsverhalten im "gläsernen Demonstrator", in Proc. Deutsche Kälte-Klima-Tagung 2025, Magdeburg, Germany, 2025/11/20-2025/11/21 -------------------------- METHODOLOGICAL INFORMATION -------------------------- This conference paper analyzes experimentally determined material properties (e.g., thermal stability, corrosion behavior, heat capacity, contact angle) of the material pairs H2O/[EMIM][MeSO3] and H2O/Betain:Glycerol. In addition, the thermal and flow characteristics of H2O/[EMIM][MeSO3] are evaluated in the closed absorption heat pump process of a "glass demonstrator." In both cases, H2O/LiBr is used as a benchmark.The corresponding measurement data and evaluated results are separatly given. -------------------- DATA & FILE OVERVIEW -------------------- 00_README.txt 01_Conference_Paper_DKV_2025_Wernhart_et_al.pdf 02_Alternative_Sorbents_after_isothermal_heating.png 03_Specimens_for_simulating_contact_points_of_an_AWP_(below)_and_Test_setup_(above).png 04_Contact_angle_(74°)_of_an_H2O_[EMIM][MeSO3]_mixture.png 05_Contact_angles_of_saturated_water_adsorbent_mixtures_at_different_water_contents_and_25°C_on_stainless_steel_and_copper.png 06_Contact_angle_of_saturated_water_adsorbent_mixtures_at_operationally_relevant_water_contents_on_stainless_steel_and_copper.png 07_Measurement_results_of_cp_measurements_according_to_ASTM_E1269_[14]_(accuracy:+/-_2.5%)_as_well_as_by_Stark_et_al._[16].png 08_Hydraulic_schemata_of_the_AWP_demonstrator_including_hydraulic_connection_(left).3D_visualization_of_the_AWP_demonstrator_(right).png 09a_Cooling_capacity_depending_on_ṁ_RSo.png 09b_Cooling_capacity_depending_on_f_sat.png 10_Comparison_of_the_actual_solution_cycle_with_the_theoretically_achievable_one.png 11_Oxidation_on_'dry_spots'_in_the_generator_after_operation_with_IL,_recognizable_by_dark_discoloration.png 12_Measurement_DATA_and_results.xlsx ----------------------------------------- DATA-SPECIFIC INFORMATION FOR: Common ----------------------------------------- Symbols: β … heating rate (K/min) 𝑐𝑝 … specific heat capacity (J/(kg ∙ K)) 𝛥 … difference (−) 𝛥sig … difference signal [muV] 𝜀 … Efficiency/effectivnesss (−) f ... specific solution cycle (𝑚̇_𝑅𝑆𝑜/𝑚̇_𝑅𝑒𝑓 ) 𝜂 … dynamic viscosity (Pa ∙ s) ℎ ... specific enthalpy (kJ/kg) m ... mass (kg) 𝑚̇ ... Massenflow (kg/s) 𝑞 … steam number (kg_vap/kg_v+l) 𝑝 ... pressure (Pa) 𝑄̇ ... heat flow (W) 𝜌 ... density (kg/m3) S ... spec. reference heat capacity (J/(kg ∙ K) 𝑡 … temperatur (°C) 𝑇 … temperatur (K) 𝜏 … time (d) U ... decomposition rate (%/𝜏) 𝑉̇ ... volume flow (m3/s) w ... water loading (kgH2O/kgSol) 𝑥 ... mass fraction (kgSol/kgH2O-Sol) Abbreviations and Indices: ABS ... absorber AWP ... absorption heat pump CON ... condensator Cond ... condensation DES ... deep eutectic solvent E ... excess EVA ... evaporator evap ... evaporation FTIR Fourier-Transformations-Infraredspectrometer GEN ... generator H2O ... water as refrigerant HSo ... high temperature heat source IL ... ionic liquid in ... inlet l ... liquid LiBr ... lithium bromide LSo ... low temperature heat source NMR ... nuclear magnetic resonance out ... outlet PSo ... poor solution Ref ... refrigerant RSo ... rich solution sat ... saturated Si ... heat sink (medium temperature) SHX ... solvent heat exchanger Sol ... absorbent SP ... solvent pump v ... vapor -------------------------- SHARING/ACCESS INFORMATION -------------------------- Use citation as recommended by the repository for use of this dataset and Conference Paper. See repository for license type.