Published November 22, 2022
| Version v1
Dataset
Open
X-ray CT dataset of a secondary Li-ion Battery
- Hosting institution:
- Graz micro computed Tomography Consortium
Description
X-ray CT scan of a secondary Li-ion Battery by Eduardo Machado, Technical University of Graz. The goal was to observe the impact of mechanical deformation on the layers. Specimen scanned during a laboratory training on March 30, 2002. Isotropic voxel size = 15.5 µm. Please acknowledge Graz micro-computed Tomography Consortium and Eduardo Machado when using this data.
Technical info (English)
Scan Parameters:
- Scanner name =TESCAN UnitomXL; 180 kv reflection source; TU_Graz
- kV = 175
- Target current actual value = 171.7 µA
- Target power = 30
- Filter = Cu 1.5 mm
- Exposure = 280 ms
- Projections = 1440
- Average = 8
- Voxel size = 15.5 µm.
- SOD = 57.000076 mm
- SDD = 1100.000244 mm
- Scan type = smooth take and save
- Binning value = 2
- Unbinned pixelsize (mm) = 0.15
- Binned pixelsize (mm) = 0.3
Technical info (English)
Reconstruction Parameters (see #.rec.1.xml in directory):
- beam hardening correction = 0
- Scatter Correction = 0.01
- Noise attenuation filter = SheppLogan
- Noise attenuation value = 0.5
Files
LiBattery01 - XZ slice.png
Additional details
- Available
-
2022-11-21